Plant engineering · Lecture · Intermediate

The Electrolyzer System: Balance of Plant and Minimum Load

Hasim Software15 minEnglish

Why watch it?

What does a PEM electrolyzer plant consume beyond its stack? Lesson 5 of the Green Hydrogen Fundamentals series, presented by Prof. Hani Muhsen of Hasim Software, works through the balance of plant of a 10 MW example plant: water loop and pump, separators, heat exchanger and dry cooler, ion exchanger, deoxo unit, dryer and gas analyzer. According to the presenter, stack consumption of 50.6 kWh/kg rises to 54.7 kWh/kg at plant level once power electronics and auxiliaries are included. The lesson also shows how hydrogen crossover sets the hydrogen-in-oxygen level and the minimum load. The example is built in the publisher's own simulation software, and all figures rest on model assumptions rather than measured plant data.

This introduction is based on the video’s YouTube description and catalogue details. Source video: independent technical information. No expert opinion has been added to this video yet.

What you will learn

The viewer can compare the contribution of auxiliary systems with stack energy consumption in an example PEM plant and interpret how hydrogen crossover determines the minimum load.

Who is it for?

  • StudentCore concepts and a solid start
  • EngineerDesign, operation and system integration

Related videos

Take your hydrogen plant from feasibility to commissioning

Talk to the IPEC team about basic and detailed engineering, procurement, installation and commissioning.

Get in touch